| RAPOSA-NG uses Lithium-ion Polymer batteries (Li-Po) with 4800mAh and 14.8V.
| | #REDIRECT [[RAPOSA-NG batteries]] |
| | |
| The primary difference between this batteries and other Lithium-ion is that the lithium-salt electrolyte is not held in an organic solvent but in a solid polymer composite such as polyethylene oxide or polyacrylonitrile.
| |
| | |
| Each battery is composed of 4 cells with 2400mAh and 3.7V each, in a 4S2P fashion (two 4 series packs in parallel).
| |
| | |
| [[Image:Raposa_4s2p.jpg|499x174px|4S2P Fashion]] | |
| | |
| ==== Battery Charger ====
| |
| | |
| [[Image:RAPOSA_BATTERIES.jpg|400px|thumb|How to charge RAPOSA-NG batteries using ULTRAMAT 10]]
| |
| | |
| Currently two all-purpose fast chargers from Groupner (ULTRAMAT 10) are used to charge RAPOSA-NG batteries at the Mobile Robots Laboratory (8th floor, North Tower, IST Campus-Alameda).
| |
| | |
| | |
| To recharge RAPOSA-NG batteries using ULTRAMAT 10:
| |
| | |
| * Connect the ULTRAMAT 10 power plug to an available power socket;
| |
| | |
| * Connect the battery plug to the ULTRAMAT 10 battery socket;
| |
| | |
| * Press ENTER (the first button from the right) two times.
| |
| | |
| | |
| If the ULTRAMAT screen presents the following screen (the current and voltage displayed in this image are irrelevant)
| |
| | |
| [[Image:ULTRAMAT_CRG.jpg]]
| |
| | |
| it means that it is charging. When finished, the ULTRAMAT 10 will beep for a few seconds and the following screen (again, the current and voltage displayed in this image are irrelevant)
| |
| | |
| [[Image:Raposa_END.jpg]]
| |
| | |
| will be presented.
| |
| | |
| | |
| For any other information regarding the ULTRAMAT 10 usage, please check this manual (in Dutch, English and French):
| |
| | |
| [http://clubcugnaux.free.fr/Page_notices_techniques/ChargeurGraupnerUltramat10.pdf Battery Charger ULTRAMAT 10 manual]
| |
| | |
| ==== Risks ====
| |
| | |
| This batteries are highly dangerous when used without proprer measures. They can only be charged with appropritate Lithium-ion Polymer chargers and with the correct specifications. Crashes, high temperatures and short circuits can cause explosions. Please be extra carefull when dealing with this batteries.
| |
| | |
| ==== Precautions ====
| |
| | |
| * NO NOT use other chargers to charge the batteries, unless it is a Li-Po charger and it is correctly configured;
| |
| * Avoid recharging batteries already charged. This can reduce their live expectancy;
| |
| * Recharge a battery as soon as possible to prevent live damages;
| |
| * Never leave them recharging without any supervision, as any accident with the battery can cause a fire;
| |
| * If a battery starts to swell (or is already swollen), STOP USING IT and give them to someone that can thew them away in the proper places;
| |
| * NEVER trow a battery into the normal garbage.
| |
| | |
| | |