Turning on and off the Vizzy robot: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
=Turning Vizzy on= | =Turning Vizzy on= | ||
# Check that the Vizzy power cables are unplugged from the power source. | # Check that the Vizzy power cables are unplugged from the [[Media:Powersource.jpg|power source]]. | ||
# Set the voltage to 24.5V and rotate the current dial to the minimum. | # Set the voltage to 24.5V and rotate the current dial to the minimum. | ||
# Plug in the power source to Vizzy, and rotate the current dial to power Vizzy. | # Plug in the power source to Vizzy, and rotate the current dial to power Vizzy. |
Revision as of 13:37, 23 September 2011
Turning Vizzy on
- Check that the Vizzy power cables are unplugged from the power source.
- Set the voltage to 24.5V and rotate the current dial to the minimum.
- Plug in the power source to Vizzy, and rotate the current dial to power Vizzy.
- Check Vizzy O.K. lights.
- Check that the blue/purple lights on the larger controller boards go off (after a few seconds).
- Check that the orange lights on the smaller controller boards are blinking.
- Run the iCubInterface on the PC104.
Turning Vizzy off
- Shutdown iCubInterface on the PC104 (by pressing Ctrl-c).
- Rotate the current dial, on the power source, to its minimum.
- Unplug power source.