Revision as of 13:49, 23 September 2011
Turning Vizzy on
- Check that the Vizzy power cables are unplugged from the power source.
- Set the voltage to 24.5V and rotate the current dial to the minimum.
- Make sure the emergency button is connected to Vizzy.
- Plug in the power source to Vizzy, and rotate the current dial to power Vizzy.
- Check Vizzy O.K. lights.
- Check that the blue/purple lights on the larger control boards go off (after a few seconds).
- Check that the orange lights on the smaller control boards are blinking.
- Run the iCubInterface on the PC104.
Turning Vizzy off
- Shutdown iCubInterface on the PC104 (by pressing Ctrl-c).
- Rotate the current dial, on the power source, to its minimum.
- Unplug power source.